Related Experiment Video
Updated: Jun 28, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
The measurement of dyshemoglobins and total hemoglobin by pulse oximetry
Steven J Barker1, John J Badal
1Department of Anesthesiology, The University of Arizona College of Medicine, Tucson, Arizona 85724-5114, USA. sjbarker@u.arizona.edu
Purpose Of Review:
Recent advances in pulse oximetry have made it possible to noninvasively measure total hemoglobin, as well as the two most common dyshemoglobins. This review will trace the development and clinical application of multiwavelength pulse oximetry.
Recent Findings:
Until now, commercially produced pulse oximeters have utilized two wavelengths of light and could measure only the ratio of oxyhemoglobin to total hemoglobin, displayed as SpO2. Pulse oximeters using up to 12 light wavelengths have recently been developed by Masimo Corp. (Irvine, California, USA). These new 'Rainbow Pulse CO-oximeter' instruments can estimate blood levels of carboxyhemoglobin, methemoglobin, and total hemoglobin (SpHb), as well as the conventional SpO2 value. The accuracy of these new measurements has been studied in human volunteers and clinical trials. Some interesting case reports have documented the use of this new technology in diagnosis and treatment.
Summary:
The development of multiwavelength pulse oximeters, which can measure total hemoglobin as well as dyshemoglobins, should result in improved patient care.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse