Related Experiment Video
Updated: Jun 28, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
A method of dosimetry for synchrotron microbeam radiation therapy using radiochromic films of different sensitivity
J C Crosbie1, I Svalbe, S M Midgley
1School of Physics, Monash University, Melbourne, Victoria 3800, Australia. Jeffrey.Crosbie@sci.monash.edu.au
Abstract:
This paper describes a method of film dosimetry used to measure the peak-to-valley dose ratios for synchrotron microbeam radiation therapy (MRT). Two types of radiochromic film (manufactured by International Specialty Products, NJ, USA) were irradiated in a phantom and also flush against a microbeam collimator (beam width 25 microm, centre-to-centre spacing 200 microm) on beamline BL28 B2 at the SPring-8 synchrotron. Four experiments are reported: (1) the HD-810 and EBT varieties of radiochromic film were used to record 'peak' dose and 'valley' (regions in between peaks) dose, respectively; (2) a stack of HD-810 film sheets was microbeam-irradiated and analysed to investigate a possible dose build-up effect; (3) a very high MRT dose was delivered to HD-810 film to elicit a measurable valley dose to compare with the result obtained using broad beam radiation; (4) the half value layer of the beam with and without the microbeam collimator was measured to investigate the effect of the collimator on the beam quality. The valley dose obtained for films placed flush against the collimator was approximately 0.2% of the peak dose. Within the water phantom, the valley dose had increased to between 0.7 and 1.8% of the peak dose, depending on the depth in the phantom. We also demonstrated, experimentally and by Monte Carlo simulation, that the dose is not maximal on the surface and that there is a dose build-up effect. The microbeam collimator did not make an appreciable difference to the beam quality. The values of the peak-to-valley ratio reported in this paper are higher than those predicted by previously published Monte Carlo simulation papers.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET