Related Experiment Video
Updated: Jan 26, 2026

Author Spotlight: A Pseudotype Virus System for Assessing Omicron Subvariants and Neutralizing Antibodies in SARS-CoV-2 Research
Published on: September 8, 2023
Galectin-2 3279TT variant protects against the lymphotoxin-alpha 252GG genotype associated ischaemic stroke
Zoltan Szolnoki1, Anita Maasz, Lili Magyari
1Department of Cerebrovascular Disease, Pandy Kalman County Hospital, Gyula, Hungary. szolnoki99@hotmail.com
Objective:
The galectin-2 protein is presumed to play a regulatory role in the intracellular trafficking of the lymphotoxin-alpha (LTA) cytokine. LTA is a pro-inflammatory factor, its 252GG homozygote variant is considered as a susceptibility factor for arteriosclerosis and cardiovascular diseases. By contrast, the galectin-2-encoding gene LGALS2 3279TT homozygote variant has been demonstrated to exert protection against myocardial infarction by reducing the transcriptional level of galectin-2, thereby leading to a reduced extracellular secretion of LTA.
Methods:
In the present study, we examined whether the LGALS2 3279TT homozygote variant alone can influence the prevalence of ischaemic stroke, and whether it can interact somehow with the disadvantageous LTA 252GG homozygote variant. Genetic and clinical data of 385 ischemic stroke patients and 303 stroke and neuroimaging alteration-free controls were analysed.
Results:
The combination of the LGALS2 3279TT and LTA 252GG homozygote was significantly less frequent in the ischemic stroke group (1.56%) than in the controls (5.94%, p<0.00187; overall stroke group: crude OR: 0.25, 95% CI: 0.1-0.64; adjusted OR: 0.03, 95% CI: 0.025-0.71).
Conclusions:
This finding suggests a gene-gene interaction.
Related Concept Videos
Protecting Self-Esteem
Histone Variants at the Centromere
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...

