Related Experiment Video
Updated: Jun 27, 2026

qPCR Is a Sensitive and Rapid Method for Detection of Cytomegaloviral DNA in Formalin-fixed, Paraffin-embedded Biopsy Tissue
Published on: July 9, 2014
Detection of human cytomegalovirus-specific T lymphocytes in human blood: comparison of two methods
C M Schermann1, G Fischer, V Witt
1Clinical Immunology Laboratory, Intercell AG, Vienna, Austria.
Background:
Human cytomegalovirus (HCMV) infection remains a major cause of morbidity and mortality in immunocompromised patients undergoing allogeneic stem cell transplantation (SCT). In the case of HCMV reactivation, the well-defined detection of virus-specific effector cells in patients might positively impact antiviral treatment.
Methods:
We examined blood samples from healthy volunteers serologically typed for HCMV IgG. Based on multicolor flow cytometry analysis, we addressed HCMV-specific CD8(+) effector T lymphocytes using HCMV-specific tetramers for the respective major histocompatibility complex (MHC) class I type. As a second approach, we employed the cytokine secretion assay (CSA), which allows the indirect detection of target-specific CD4(+) and CD8(+) T cells via their interferon (IFN)-gamma secretion upon HCMV pp65 in vitro stimulation.
Results:
We hypothesized the detection of HCMV-specific lymphocytes in >50% of healthy Caucasians that were IgG-seropositive for HCMV. In terms of specificity, both assays showed comparably good results (specificity 100%, confidence interval >95%). Regarding sensitivity, both assays met the zero hypothesis. However, with 45/52 (86.5%) the tetramer technology was superior to the CSA, which detected 34/52 (65.4%) based on CD8(+) T cells and 41/52 (78.8%) based on both CD4(+) and CD8(+) T cells.
Discussion:
A good correlation was observed between both assays, although the tetramers addressed only CD8(+) HCMV-specific T cells, whereas IFN-gamma secretion was detected on all T-cell types. Disadvantages of the CSA are the time-consuming stimulation, the extensive cell washing steps and the fact that the target cells are detected indirectly. The analysis with tetramers is rapid and reliable but their general use is hampered because of the restriction to a few HLA types.
More Related Videos
06:03Whole Blood Assay with Dual Co-Stimulation for Antigen-Specific Analysis of Host Immunity to Fungal and Viral Pathogens
Published on: September 20, 2024
08:04Development of an IFN-γ ELISpot Assay to Assess Varicella-Zoster Virus-specific Cell-mediated Immunity Following Umbilical Cord Blood Transplantation
Published on: July 9, 2014