Study Objective:
To determine if the previously described single-step O(2)/N(2)O fresh gas flow (FGF) sequence could be combined with a simple desflurane vaporizer (F(D)) sequence to maintain the end-expired desflurane (F(A)des) at 4.5% with the anesthesia delivery unit machine (ADU Anesthesia Machine(R); General Electric, Helsinki, Finland).
Design:
Prospective randomized clinical study.
Setting:
Onze Lieve Vrouw Hospital, Aalst, Belgium, a large teaching hospital.
Patients:
42 ASA physical status I and II patients requiring general endotracheal anesthesia and controlled mechanical ventilation.
Interventions:
In 18 patients undergoing general anesthesia with controlled mechanical ventilation, F(D) was determined to maintain F(A)des at 4.5% with O(2)/N(2)O FGF of two and 4 L per minute for three minutes and 0.3 and 0.4 L per minute thereafter. Using the same FGF sequence, we prospectively tested the F(D) schedule that approached this observed F(D) pattern with the fewest possible adjustments in another 24 patients.
Main Results:
F(D) of 6.5% for 15 minutes followed by 5.5% thereafter approximated the observed F(D) course well. When it was prospectively tested, the median (25th, 75th percentiles) performance error was -1% (-5.1%, 5.2%); absolute performance error, 7.1% (3.9%, 9.5%); divergence, -6.6% per hour (23.1%, 3.1%/h); and wobble, 2.2% (1.8%, 3.2%). Because F(A)des increased above 4.9%, F(D) was decreased in 5 patients after 23 minutes (0.5% decrement once or twice); in two patients, F(D) was temporarily increased. In one patient, FGF was temporarily increased because the bellows volume became insufficient.
Conclusions:
One O(2)/N(2)O rotameter FGF setting change from 6 to 0.7 L per minute after three minutes and one desflurane F(D) change from 6.5% to 5.5% after 15 minutes maintained anesthetic gas concentrations within predictable and clinically acceptable limits during the first 20 minutes.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
03:02Application of Dixon's Up-and-Down Design to Estimate the Minimum Alveolar Concentration of Sevoflurane in Rats with Refined Movement Classification
Published on: July 25, 2025
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Inhalational Anesthetics: Overview
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management