Radiographic film dosimetry for IMRT fields in the nearsurface buildup region
Peter L Roberson1, Jean M Moran1, Ravi Kulasekere1
1Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan, U.S.A.
Abstract:
Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work demonstrates that film dosimetry can accurately predict the dose in the buildup region for IMRT, since 1) film dosimetry can be performed with sufficient accuracy for small fields and 2) IMRT is delivered by a series of "small" segments (step and shoot IMRT). This work evaluates the accuracy of X-OMAT V (XV) and Extended Dose Range (EDR) film for measurements from 2 mm to 15 mm depths for small fields and clinical IMRT beams. Film measurements have been compared to single point measurements made with a stereotactic diode and parallel plate ionization chamber (P11) and thermoluminescent dosimeters (TLD) at various depths for square (diode, P11) and IMRT (diode, TLD) fields. Film calibration was performed using an 8-field step exposure on a single film at 5 cm depth, which has been corrected to represent either small field or large field depth dependent film calibration techniques. Up to 10% correction for film response variation as a function of depth was required for measurements in the buildup region. A depth-dependent calibration can sufficiently improve the accuracy for IMRT calculation verification (i.e., < or = 5% uncertainty). A small field film calibration technique was most appropriate for IMRT field measurements. Improved buildup region dose measurements for clinical IMRT fields promotes improved dose estimation performance for (inverse) treatment planning and allows more quantitative treatment delivery validation.
More Related Videos
Related Concept Videos
X-ray Imaging
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...