Related Experiment Video
Updated: Jun 27, 2026

Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Compensator-based intensity-modulated radiation therapy for malignant pleural mesothelioma post extrapleural
Khosrow Javedan1, Craig W Stevens2, Kenneth M Forster2
1Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, and Radiation Oncology, Tampa, Florida, U.S.A.
Abstract:
The present work investigated the potential of compensator-based intensity-modulated radiation therapy (CB-IMRT) as an alternative to multileaf collimator (MLC)-based intensity-modulated radiation therapy (IMRT) to treat malignant pleural mesothelioma (MPM) post extrapleural pneumonectomy. Treatment plans for 4 right-sided and 1 left-sided MPM post-surgery cases were generated using a commercial treatment planning system, XIO/CMS (Computerized Medical Systems, St. Louis, MO). We used a 7-gantry-angle arrangement with 6 MV beams to generate these plans. The maximum required field size was 30 x 40 cm. We evaluated IMRT plans with brass compensators (.Decimal, Sanford, FL) by examining isodose distributions, dose-volume histograms, metrics to quantify conformal plan quality, and homogeneity. Quality assurance was performed for one of the compensator plans. Conformal dose distributions were achieved with CB-IMRT for all 5 cases, the average planning target volume (PTV) coverage being 95.1% of the PTV volume receiving the full prescription dose. The average lung V20 (volume of lung receiving 20 Gy) was 1.8%, the mean lung dose was 6.7 Gy, and the average contralateral kidney V15 was 0.6%. The average liver dose V30 was 34.0% for the right-sided cases and 10% for the left-sided case. The average monitor units (MUs) per fraction were 980 MUs for the 45-Gy prescriptions (mean: 50 Gy) and 1083 MUs for the 50-Gy prescriptions (mean: 54 Gy). Post surgery, CB-IMRT for MPM is a feasible IMRT technique for treatment with a single isocenter. Compensator plans achieved dose objectives and were safely delivered on a Siemens Oncor machine (Siemens Medical Solutions, Malvern, PA). These plans showed acceptably conformal dose distributions as confirmed by multiple measurement techniques. Not all linear accelerators can deliver large-field MLC-based IMRT, but most can deliver a maximum conformal field of 40 x 40 cm. It is possible and reasonable to deliver IMRT with compensators for fields this size with most conventional linear accelerators.
More Related Videos
09:31Orthotopic Implantation and Peripheral Immune Cell Monitoring in the II-45 Syngeneic Rat Mesothelioma Model
Published on: October 2, 2015
04:04Endobronchial Ultrasound-guided Intratumoral Injection of Cisplatin for the Treatment of Isolated Mediastinal Recurrence of Lung Cancer
Published on: February 12, 2017
Related Concept Videos
Pleural Disorders: Types and Brief Description
Pneumothorax-II
Clinical Manifestations:
Pleural Effusion II: Symptoms and Management
A pleural effusion is the abnormal collection of fluid between the parietal and visceral pleura layers of tissue that form the lining of the lungs and chest cavity. It can occur independently or due to surrounding parenchymal diseases, such as infection, malignancy, or inflammatory conditions.
Clinical Manifestations: