A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
[A novel capsule-style manometric system and its application on non-invasive measurement of pancolonic pressure]
Wenqiang Zhang1, Guozheng Yan, Lianzhi Yu
1Institute of Medical Precise Instrumentation, Shanghai Jiaotong University, Shanghai 200240, China. zwq2006@hotmail.com
Abstract:
Pan-colonic motility was studied under normal conditions with a novel capsule-style system. A single use telemetry capsule embedded with one pressure sensor was ingested by subjects. It is capable of transmitting colonic pressure wirelessly greater than 130 h. Time of capsule entering segmental colon was determined by ultrasonic detection for tracing the batteries in capsule. The ultrasonic electrodes were mounted on the surface of subjects' ileocecum, navel as well as the junction of left colon and rectosigmoid colon in sequence. They were identified by abdominal X-rays with radiopaque markers. The confirming X-rays showed all telemetry capsules were detected successfully when passing through the key points in colon. A total of 613 h of colorectal recording was obtained from 20 healthy subjects. When compared with the parameters in the time of waking, the number of contractions and the area under contractions were significantly (P<0.05) decreased during sleep (21 +/- 5 vs 15 +/- 4 h(-1); 463 +/- 54 vs 342 +/- 45 mmHg x s x min(-1)). The colonic motility exhibited significant regional variation in the circadian behavior, as well as in its response to waking and meal. The clinical study proved the reliability and non-invasiveness of the system. It may represent a useful tool for the study on physiology and pathology of colonic motor disorders.
Related Concept Videos
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Pressure Gauges
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement