Experimental band compression factor of a neutral compound under high pressure gradient elution
Fabrice Gritti1, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
To measure the gradient compression factor for a low molecular weight compound (caffeine, MW=194 g/L), 1 microL samples of solution were injected into a 2.1 mm x 100 mm column packed with bridged ethylsiloxane BEH-silica. These samples were successively run under isocratic and gradient elution modes. Both chromatograms were recorded with either a low (<250 bar) or a high pressure drop (>650 bar), corresponding to flow rates of 0.10 and 0.35 mL/min, respectively. Caffeine was eluted with a mixture of methanol and water at room temperature. The efficiency and the retention factors of caffeine on the BEH-C(18)column were measured as a function of the mobile phase composition under isocratic conditions. During the gradient elution, the methanol concentration was increased from 10 to 25% (v/v). The experimental compression factors measured are in excellent agreement with those predicted with an equation previously derived, which is valid at low flow rates and for smooth gradients. The negative relative difference observed between experimental and theoretical values at high flow rates originates from the compressibility of the eluent. Using a high gradient steepness to perform fast gradient elution limits the degree of band compression that can be achieved, even when the radial temperature gradient across the column is as small as 0.2K.
More Related Videos
10:36Stress Distribution During Cold Compression of Rocks and Mineral Aggregates Using Synchrotron-based X-Ray Diffraction
Published on: May 20, 2018
08:42High-Sensitivity Nuclear Magnetic Resonance at Giga-Pascal Pressures: A New Tool for Probing Electronic and Chemical Properties of Condensed Matter under Extreme Conditions
Published on: October 10, 2014
Related Concept Videos
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...