Vessel asymmetry as an additional diagnostic tool in the assessment of abdominal aortic aneurysms
Barry J Doyle1, Anthony Callanan, Paul E Burke
1Department of Mechanical and Aeronautical Engineering, Centre for Applied Biomedical Engineering Research, Materials and Surface Science Institute, University of Limerick, Limerick, Ireland.
Objective:
Abdominal aortic aneurysm (AAA) rupture is believed to occur when the local mechanical stress exceeds the local mechanical strength of the wall tissue. On the basis of this hypothesis, the knowledge of the stress acting on the wall of an unruptured aneurysm could be useful in determining the risk of rupture. The role of asymmetry has previously been identified in idealized AAA models and is now studied using realistic AAAs in the current work.
Methods:
Fifteen patient-specific AAAs were studied to estimate the relationship between wall stress and geometrical parameters. Three-dimensional AAA models were reconstructed from computed tomography scan data. The stress distribution on the AAA wall was evaluated by the finite element method, and peak wall stress was compared with both diameter and centerline asymmetry. A simple method of determining asymmetry was adapted and developed. Statistical analyses were performed to determine potential significance of results.
Results:
Mean von Mises peak wall stress +/- standard deviation was 0.4505 +/- 0.14 MPa (range, 0.3157-0.9048 MPa). Posterior wall stress increases with anterior centerline asymmetry. Peak stress increased by 48% and posterior wall stress by 38% when asymmetry was introduced into a realistic AAA model.
Conclusion:
The relationship between posterior wall stress and AAA asymmetry showed that excessive bulging of one surface results in elevated wall stress on the opposite surface. Assessing the degree of bulging and asymmetry that is experienced in an individual AAA may be of benefit to surgeons in the decision-making process and may provide a useful adjunct to diameter as a surgical intervention guide.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Aneurysm III: Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...