Related Experiment Video
Updated: Jun 27, 2026

Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Foreign body ingestion: comparison of diagnostic accuracy of computed tomography versus endoscopy
1Department of Diagnostic Radiology and Organ Imaging, United Christian Hospital, Kowloon, Hong Kong SAR. lukwinghang@gmail.com
Purpose:
To investigate and compare the sensitivity and specificity of computed tomography and of endoscopy, as diagnostic tests for foreign body ingestion.
Materials And Methods:
Over a two-year period, Asian patients with suspected foreign body ingestion were studied. The clinical findings, computed tomography images, endoscopic results, treatment and outcomes were prospectively analysed.
Results:
Over the study period, 193 patients were admitted for foreign body ingestion, complaining of a persistent foreign body sensation in the neck. The sensitivity and specificity of computed tomography were 78 and 96 per cent, respectively; the positive predictive value was 75 per cent and the negative predictive value 97 per cent. The diagnostic accuracy of computed tomography was 94 per cent.
Conclusion:
Our study showed that computed tomography had high negative predictive value and accuracy in the diagnosis of foreign body ingestion. It was useful if endoscopy showed negative findings but the patient still had persistent symptoms of foreign body ingestion.
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Computed Tomography
Endoscopic Procedures V: ERCP
Patient...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...