Related Experiment Video
Updated: Jun 27, 2026

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
Published on: May 1, 2020
A biomechanical basis for tears of the human acetabular labrum
C D Smith1, S Masouros, A M Hill
1Department of Bioengineering, Imperial College London, Royal School of Mines, South Kensington Campus, London, UK. drcs1@doctors.net.uk
Objective:
Acetabular labral tears predominantly affect young patients and are a source of hip pain in the athlete. Four causes of the initiation of labral tears have been proposed; trauma, hypolaxity of the anterior capsule, dysplasia and bony impingement. A further cause could be reduced biomechanical properties in the area most susceptible to tears. However, no work has defined these properties.
Design:
32 compressive and 32 tensile test samples were harvested from fresh-frozen cadaveric acetabula. The labrum was divided into eight areas to allow comparison around its circumference. Semiconfined compressive testing and tensile testing were performed at a displacement rate of 10 mm/min in a controlled environment of 100% humidity at 37 (SD 1) degrees C.
Setting:
Cadaveric study.
Results:
The mean compressive stiffness was 31.75 (SD 16.7) MPa, and the mean tensile elastic modulus was 24.7 (SD 10.8) MPa. The anterosuperior region had a significantly lower compressive elastic modulus than either of the posterior quadrants (p<0.05) and a significantly lower tensile modulus to the anterioinferior area (p<0.05).
Conclusions:
The biomechanical properties in the anterosuperior region may be a contributing factor to the initiation of labral tears.
Related Concept Videos
Bones of the Lower Limb: Femur and Patella
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...