[Comparison of oxygen saturation among newborns with bronchopulmonary dysplasia during and after feeding]
Carlos Antonio Tapia-Rombo1, Gabriela Munguía-Medina, Víctor Joel Saucedo-Zavala
1Servicio de Neonatología, Unidad Médica de Alta Especialidad, Hospital General, Centro Médico Nacional La Raza, IMSS, México D.F., México. tapiachar@yahoo.com.mx
Insights
Infants with bronchopulmonary dysplasia (BPD) experience significant oxygen drops during feeding. Supplemental oxygen is crucial to maintain adequate peripheral oxygen saturation (SpO2) above 88% in these vulnerable infants.
Area of Science:
- Neonatal Medicine
- Pediatric Pulmonology
- Critical Care
Background:
- Bronchopulmonary dysplasia (BPD) frequently causes hypoxemia, particularly during infant feeding.
- Monitoring oxygenation is critical for managing BPD complications.
Purpose of the Study:
- To assess peripheral oxygen saturation (SpO2) in infants diagnosed with BPD.
- To analyze SpO2 trends before, during, and after feeding sessions.
Main Methods:
- Prospective study of BPD patients from July to September 2005.
- Peripheral oxygen saturation (SpO2) measured five times per feeding event using digital pulsioxymetry.
- Statistical analysis with alpha levels set at p<0.05.
Main Results:
- 18 BPD patients and 67 feeding events were analyzed, totaling 335 SpO2 recordings.
- 16 out of 18 patients experienced frequent desaturation events (SpO2 < 88%) during feeding.
- 67% of participants (n=12) showed SpO2 levels dropping to 80% during recordings (p<0.001).
Conclusions:
- Feeding significantly decreases SpO2 in BPD infants, with severe desaturations (SpO2 < 80%) occurring in two-thirds of cases.
- Increased oxygen concentration during feeding is recommended to maintain SpO2 levels at or above 88%.
Background:
Bronchopulmonary dysplasia (BPD) is associated with frequent events of hypoxemia specially during feeding.
Objective:
Determine peripheral oxygen saturation (SpO2) among infants with BPD before, during and after feeding.
Methods:
Patients with diagnosis of BPD were prospectively studied between July-September, 2005. SpO2 was measured with a manual digital pulsioxymeter 5 times during feeding. Alpha levels were set at p<0.05.
Results:
67 events were studied in 18 patients. For each participant, oxygen saturation was measured five times yielding a total of 335 recordings. Frequent desaturation episodes were recorded during feeding, (SpO2<88%) in 16 of the 18 cases. SpO2 reached 80% for some recordings among 67% of participants (n=12), with p<0.001.
Conclusion:
Among BDP patients, SpO2 decreases during feeding, reaching severe desaturations (SpO2<80%) among in two thirds of the cases. Oxygen concentration must be sufficiently increased during feeding in order to rise the level of SpO2 to a minimum of 88%.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...