Load-independent parameters of diastolic and systolic function by speckle tracking and tissue doppler in hemodialysis

Lígia Mendes1, Regina Ribeiras, Teresa Adragão

  • 1Serviço de Cardiologia, Hospital de Santa Cruz, Carnaxide, Portugal. ligiamendes76@gmail.com

Insights

New echocardiographic methods show that E/Em ratios are load-independent for assessing diastolic function in end-stage renal disease patients undergoing hemodialysis. Systolic function parameters also remained load-independent, with similar results across different imaging techniques.

Area of Science:

  • Cardiology
  • Nephrology
  • Medical Imaging

Background:

  • Conventional Doppler echocardiography for diastolic function assessment is limited by volume load dependency.
  • The load-independence of novel echocardiographic methods for evaluating left ventricular systolic and diastolic function remains debated.

Purpose of the Study:

  • To identify load-independent echocardiographic parameters for systolic and diastolic function in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD).
  • To evaluate the agreement between new echocardiographic methods for assessing cardiac function in ESRD patients.

Main Methods:

  • 20 stable ESRD patients undergoing HD had echocardiograms before and after dialysis.
  • Parameters assessed included left ventricular volumes, ejection fraction, transmitral Doppler flow (E/A), mitral annular velocities (Em, Am) via pulsed tissue Doppler imaging (TDI), and strain via color TDI and speckle tracking imaging (STI).
  • E/Em and Am/Em ratios were calculated using spectral Doppler, pulsed TDI, color TDI, and STI.

Main Results:

  • Hemodialysis led to significant decreases in left atrial and ventricular volumes and transmitral flow.
  • Early diastolic myocardial velocities (Em) significantly decreased post-HD, indicating volume load dependency.
  • Systolic function parameters, including ejection fraction and myocardial velocities/strain, remained unchanged and appeared load-independent.
  • E/Em ratios were also found to be load-independent.

Conclusions:

  • Early diastolic myocardial velocity (Em) is volume load-dependent in ESRD patients undergoing HD.
  • E/Em ratios and systolic function parameters are load-independent, offering reliable assessment despite volume status changes.
  • Pulsed TDI, color TDI, and STI provide consistent results for evaluating myocardial systolic and diastolic function.
Abstract

Related Concept Videos

Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...