Related Experiment Video
Updated: Jun 27, 2026

Implementation of a Reference Interferometer for Nanodetection
Published on: April 26, 2014
Fringe jump analysis and electronic corrections for the Tore Supra far infrared interferometer
1CEA, IRFM, F-13108 Saint Paul Lez Durance, France. christophe.gil@cea.fr
Abstract:
On the Tore Supra tokamak, the ten-channel far infrared interferometer consists of a double color (119 and 195 microm) system with two detectors for each channel to measure the plasma density. The phase measurement is obtained by combining a 100 kHz shifted reference beam with the probing beam that has crossed the plasma. The achieved precision--a few percent of a fringe--is very good compared with the expected variations due to plasma, which are on the order of several fringes. However, the counting of the fringe variations can be affected when the signal is perturbed by electromagnetic interferences or when it deviates in the presence of strong plasma refraction changes occurring during ICRH breakdowns, pellet injections, or disruptions. This induces a strong decrease in the reliability of the measurement, which is an important concern when the diagnostic is used for density control. We describe in this paper the renewing of the electronics that has been achieved to reduce and correct the number of the so-called fringe jumps. A new zero crossing method for phase measurement is used, together with a field programmable gate array semiconductor integration, to measure the phase and activate the algorithm of corrections every 10 micros. Comparisons between a numerical oscilloscope analysis and the corrected acquired data in the case of laboratory amplitude modulation tests and in the case of real plasma perturbations are also discussed.
More Related Videos
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
11:34High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
Published on: December 3, 2013
Related Concept Videos
Atomic Emission Spectroscopy: Interference
Interference and Diffraction
IR Frequency Region: X–H Stretching
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrometers