A short-pulse K(a)-band instrumentation radar for foliage attenuation measurements
Mikko Puranen1, Pekka Eskelinen
1Metrology Research Institute, Helsinki University of Technology, Otakaari 5A, Espoo 02150, Finland.
Abstract:
A portable K(a)-band instrumentation radar for foliage attenuation measurements has been designed. It uses direct dielectric resonator oscillator multiplier pulse modulation giving a half power pulse width of 17 ns. The dual conversion scalar receiver utilizes either a digital storage oscilloscope in envelope detection format or a special gated comparator arrangement providing 1 m resolution and associated led seven segment display for data analysis. The calibrated dynamic range is better than 37 dB with an equivalent noise floor of 0.005 dBsm at 25 m test range distance. First experiments indicate an effective beamwidth close to 1 degree. The total weight is below 5 kg and the unit can be mounted on a conventional photographic tripod. Power is supplied from a 12 V/6 A h sealed lead acid battery giving an operating time in excess of 10 h.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Pulse
The pulse serves as a clinical indicator...
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2. The spectrum...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation