Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
Restarting Stalled Replication Forks02:37

Restarting Stalled Replication Forks

DNA replication is initiated at sites containing predefined DNA sequences known as origins of replication. DNA is unwound at these sites by the minichromosome maintenance (MCM) helicase and other factors such as Cdc45 and the associated GINS complex.The unwound single strands are protected by replication protein A (RPA) until DNA polymerase starts synthesizing DNA at the 5’ end of the strand in the same direction as the replication fork. To prevent the replication fork from falling apart, a...
Restarting Stalled Replication Forks02:37

Restarting Stalled Replication Forks

DNA replication is initiated at sites containing predefined DNA sequences known as origins of replication. DNA is unwound at these sites by the minichromosome maintenance (MCM) helicase and other factors such as Cdc45 and the associated GINS complex.The unwound single strands are protected by replication protein A (RPA) until DNA polymerase starts synthesizing DNA at the 5’ end of the strand in the same direction as the replication fork. To prevent the replication fork from falling apart, a...
Sequence Networks of Rotating Machines01:24

Sequence Networks of Rotating Machines

A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
Network Function of a Circuit01:25

Network Function of a Circuit

Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
Electrical Synapses01:28

Electrical Synapses

Electrical synapses found in all nervous systems play important and unique roles. In these synapses, the presynaptic and postsynaptic membranes are very close together (3.5 nm) and are actually physically connected by channel proteins forming gap junctions.
Gap junctions allow the current to pass directly from one cell to the next. In contrast, in the chemical synapse, the neurotransmitters carry the information through the synaptic cleft from one neuron to the next. They consist of two...