Published on: May 26, 2023
A novel method to measure mitral valve chordal tension
Zhaoming He1, Christopher Jowers
1Department of Mechanical Engineering, Texas Tech University, 7th Street and Boston Avenue, P.O. Box 41021, Lubbock, TX 79409, USA. zhaoming.he@ttu.edu
Abstract:
Proper leaflet coaptation of the mitral valve is vital for a healthy functioning heart. Chordal tension directly affects leaflet coaptation. The C-shaped transducer used previously to measure chordal tension was too big for tension measurement of multiple chordae and their branches. A new method is needed to measure chordal tension with minimum interference with chord and leaflet motion. The method was to extrapolate longitudinal chordal tension from transverse chordal fibril force measured by inserting a small elliptical AIFP4 sensor from MicroStrain Inc. (Williston, VT) through a chord. Sensitivity of the method has been tested with the sensor implanted in chordae, and error of the method has been estimated at various sensor deviation angles. Intact porcine and ovine hearts were used to measure mitral valve strut and marginal chordal tensions at static transmitral pressures of 120 mm Hg and 160 mm Hg under an in vitro condition. The results obtained from the AIFP4 sensor were similar to the results obtained previously by C-shaped transducers in the porcine mitral valves. The sensor output errors increased with the increase in sensor deviation angle in the chord at a peak systolic tension. Strut chordal tensions of four ovine mitral valves of Edwards ring size M 28 were 0.29+/-0.06 N at the transmitral pressure of 120 mm Hg. The tension of 18 porcine strut chordae of porcine mitral valves of Edwards ring size M 32 was 1.00+/-0.42 N at the transmitral pressures of 120 mm Hg. The tension of 22 anterior leaflet marginal chordae from porcine mitral valves of Edwards ring size M 32 was 0.10+/-0.04 N at the transmitral pressure of 120 mm Hg. A new method using an AIFP4 miniature force sensor to measure mitral valve chordal tension indirectly is successfully developed. This force sensor works well in measuring mitral valve chordal tension at an in vitro hydrostatic transmitral pressure. The size and simple fixation of the sensor make it favorable for chordal tension measurement of multiple chordae and their branches under in vitro or in vivo conditions with minimal interference with chordal geometry and dynamics.
Related Concept Videos
Mitral Valve Prolapse III: Nursing Management
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse I: Introduction
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Tension
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...