Related Experiment Video
Updated: Jun 27, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Bolus calculator: a review of four "smart" insulin pumps
Howard Zisser1, Lauren Robinson, Wendy Bevier
1Sansum Diabetes Research Institute, Santa Barbara, California 93105, USA. hzisser@sansum.org
Abstract:
Abstract The use of continuous subcutaneous insulin infusion (CSII) pumps has been gaining popularity since 1979, when the first research report on insulin pumps was published. Insulin pumps-small medical devices that are programmed to infuse insulin through a catheter placed under the skin-are a replacement for multiple daily injections of insulin. They are currently being used by 375,000 people with type 1 diabetes, many of whom prefer CSII to multiple daily injections because of the increased flexibility of diet and exercise, increased convenience and precision when dosing, and better predictability of blood glucose levels that insulin pumps can provide when used correctly. Recent pump manufacturers have engineered a new feature called a bolus calculator, which calculates bolus insulin doses based on input from the pump wearer, which functions to help patients obtain optimum control over blood glucose levels. The bolus calculator takes into account the patient's current blood glucose, target blood glucose, amount of carbohydrate consumed, and other factors such as insulin sensitivity and insulin-to-carbohydrate ratio as well as duration of insulin action ("insulin on board"). Each pump company calculates insulin doses in a slightly different way. This article will review differences in bolus calculator recommendations between four insulin pumps, as well as errors that may occur when using bolus calculators. It will also include an in silico simulation of a meal followed by a snack using multiple insulin decay curves.
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into rapid-acting...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution