Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
Chromatographic Resolution01:15

Chromatographic Resolution

In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Column Efficiency: Rate Theory01:12

Column Efficiency: Rate Theory

The rate theory of chromatography provides quantitative insight into the shapes and widths of elution bands. These bands are based on the random-walk mechanism governing molecular migration within a column. The Gaussian profile of chromatographic bands arises from the cumulative effect of random molecular motions as they progress through the column.
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
Column Efficiency: Plate Theory01:10

Column Efficiency: Plate Theory

Band broadening in a chromatography column is measured by its efficiency. This is determined by the number of theoretical plates (N). Theoretical plate theory states that a separation column consists of a continuous series of imaginary plates where solute equilibration occurs between stationary and mobile phases.
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Retention prediction in reversed-phase liquid chromatography using XGBoost-based quantitative structure-retention relationships models.

Journal of chromatography. A·2026
Same author

Graphical Visualization Approach for Two-Dimensional Liquid Chromatography with Parallel Column Arrays.

ACS measurement science au·2026
Same author

Significance of radial dispersion to effective modulation in two-dimensional liquid chromatography.

Journal of chromatography. A·2025
Same author

Does column length still matter? A case study of the effect of column length on resolution of therapeutic oligonucleotides.

Journal of chromatography. A·2025
Same author

Effect of flow rate on plate height and resolution for antisense oligonucleotides under hydrophilic interaction liquid chromatography conditions.

Journal of chromatography. A·2025
Same author

Improved hydrophobic subtraction model of reversed-phase liquid chromatography selectivity based on a large dataset with a focus on isomer selectivity.

Journal of chromatography. A·2024

Related Experiment Video

Updated: Jun 27, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

Equation for peak capacity estimation in two-dimensional liquid chromatography.

Xiaoping Li, Dwight R Stoll, Peter W Carr

    Analytical Chemistry
    |December 5, 2008
    PubMed
    Summary

    A new equation for two-dimensional liquid chromatography (2DLC) peak capacity accounts for under-sampling. Faster second dimension separations are crucial for analysis time and peak capacity, especially with under-sampled first dimensions.

    More Related Videos

    Curtain Flow Column: Optimization of Efficiency and Sensitivity
    06:44

    Curtain Flow Column: Optimization of Efficiency and Sensitivity

    Published on: June 12, 2016

    Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
    14:42

    Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

    Published on: September 23, 2021

    Related Experiment Videos

    Last Updated: Jun 27, 2026

    Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
    08:40

    Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

    Published on: January 20, 2022

    Curtain Flow Column: Optimization of Efficiency and Sensitivity
    06:44

    Curtain Flow Column: Optimization of Efficiency and Sensitivity

    Published on: June 12, 2016

    Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
    14:42

    Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

    Published on: September 23, 2021

    Area of Science:

    • Analytical Chemistry
    • Chromatography

    Background:

    • Two-dimensional liquid chromatography (2DLC) enhances resolving power and peak capacity.
    • Traditional peak capacity calculations overestimate performance due to under-sampling.
    • Optimizing 1D vs. 2DLC separations requires accurate peak capacity metrics.

    Discussion:

    • A novel equation for effective 2DLC peak capacity corrects for first-dimension under-sampling.
    • Analysis time and overall peak capacity are significantly influenced by the second dimension's speed.
    • Under-sampling in the first dimension critically impacts 2DLC performance.

    Key Insights:

    • The derived equation provides a more accurate assessment of 2DLC resolving power.
    • Second dimension separation speed is vital for both analysis time and peak capacity.
    • First dimension optimization is less critical for shorter 2DLC runs than previously thought.

    Outlook:

    • This work offers improved guidance for optimizing 2DLC methods.
    • Accurate peak capacity calculations facilitate better comparisons between 1D and 2DLC.
    • Re-evaluation of first dimension optimization strategies for 2DLC is warranted.