Platelet function in clinically healthy cats and cats with hypertrophic cardiomyopathy: analysis using the Platelet

Karl E Jandrey1, Jeffrey W Norris, Kristin A MacDonald

  • 1Departments of Surgical and Radiological Sciences, University of California-Davis, CA 95616, USA. kejandrey@ucdavis.edu

Insights

Platelet Function Analyzer-100 (PFA-100) closure time (CT) did not significantly differ between healthy cats and those with hypertrophic cardiomyopathy (HCM). This study establishes a feline reference interval for CT, useful for future feline hypercoagulability research.

Area of Science:

  • Veterinary Medicine
  • Cardiology
  • Hematology

Background:

  • Hypercoagulability assessment in cats lacks simple analytical tools.
  • The Platelet Function Analyzer-100 (PFA-100) measures platelet function via closure time (CT).
  • Hypertrophic cardiomyopathy (HCM) in cats may be associated with hypercoagulability and thromboembolic events.

Purpose of the Study:

  • Establish a feline reference interval for PFA-100 CT.
  • Measure CT in cats with HCM.
  • Compare CT between healthy cats and cats with HCM.

Main Methods:

  • Analyzed citrated blood samples from 42 healthy cats and 30 cats with HCM.
  • Measured CT in triplicate using the PFA-100 according to manufacturer specifications.
  • Compared CT data using Student's t-test and ANOVA.

Main Results:

  • Median CT for healthy cats was 64 seconds (range 43-176 seconds).
  • Median CT for cats with HCM was 74 seconds (range 48-197 seconds).
  • No significant difference in CT was found between healthy cats and cats with HCM, or among different HCM severity groups.

Conclusions:

  • A feline reference interval for PFA-100 CT was established.
  • Cats with HCM do not exhibit significantly shorter CTs compared to healthy cats.
  • Findings suggest PFA-100 CT may not be a reliable indicator of hypercoagulability in feline HCM.