Related Experiment Video
Updated: Jun 27, 2026

Quantifying Mixing using Magnetic Resonance Imaging
Published on: January 25, 2012
Magnetic resonance velocity imaging of liquid and gas two-phase flow in packed beds
M H Sankey1, D J Holland, A J Sederman
1Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA, UK.
Abstract:
Single-phase liquid flow in porous media such as bead packs and model fixed bed reactors has been well studied by MRI. To some extent this early work represents the necessary preliminary research to address the more challenging problem of two-phase flow of gas and liquid within these systems. In this paper, we present images of both the gas and liquid velocities during stable liquid-gas flow of water and SF(6) within a packing of 5mm spheres contained within columns of diameter 40 and 27 mm; images being acquired using (1)H and (19)F observation for the water and SF(6), respectively. Liquid and gas flow rates calculated from the velocity images are in agreement with macroscopic flow rate measurements to within 7% and 5%, respectively. In addition to the information obtained directly from these images, the ability to measure liquid and gas flow fields within the same sample environment will enable us to explore the validity of assumptions used in numerical modelling of two-phase flows.
Related Concept Videos
Magnetic Resonance Imaging
Steady, Laminar Flow Between Parallel Plates