Related Experiment Video
Updated: Jun 27, 2026

A Fluorescence Fluctuation Spectroscopy Assay of Protein-Protein Interactions at Cell-Cell Contacts
Published on: December 1, 2018
Subcellular S-factors for low-energy electrons: a comparison of Monte Carlo simulations and continuous-slowing-down
D Emfietzoglou1, K Kostarelos, P Hadjidoukas
1Medical Physics Laboratory, University of Ioannina Medical School, Ioannina, Greece.
Purpose:
To study the energy deposition by low-energy electrons in submicron tissue-equivalent targets by comparing two widely used methodologies, namely, the continuous-slowing-down-approximation (CSDA) convolution integral and the Monte Carlo (MC) simulation.
Methods:
An MC track-structure code that simulates collision-by-collision the complete slowing down process is used to calculate the energy deposition in spherical volumes of unit density water medium. Comparisons are made with calculations based on the CSDA convolution integral using both empirical and MC-based range-energy analytic formulae.
Results:
We present self-irradiation absorbed fractions and S-factors for monoenergetic electrons of initial energies from 0.1-10 keV distributed uniformly in spheres of 5, 10, 50, 100, 500, and 1000 nm radius. The MC and CSDA results were found, in some cases, to differ by a factor of 2 or more; differences generally increase with decreasing sphere size. Contrary to high energies, the uncertainties associated with the straight-ahead approximation implicit in the CSDA calculations are of the same order as those related to straggling and delta-ray effects.
Conclusion:
The use of the CSDA methodology may be unsuitable for the sub-micron scale where a more realistic description of electron transport becomes important.
Related Concept Videos
The Electron Transport Chain
Inhibitors of the electron transport chain
Rotenone, a widely used pesticide, prevents electron transfer from Fe-S cluster to ubiquinone or Q in...
Molecular Kinetic Energy
Non-equilibrium in the Cell
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fermi Level Dynamics
Electron affinity in semiconductors refers to the energy gap between the minimum of its conduction band and the vacuum level and it is a critical parameter in determining how easily a semiconductor can accept additional electrons.
The work...
Calculating Standard Free Energy Changes

