Related Experiment Video
Updated: Jun 27, 2026

Coherent anti-Stokes Raman Scattering (CARS) Microscopy Visualizes Pharmaceutical Tablets During Dissolution
Published on: July 4, 2014
Quantification of atorvastatin calcium in tablets by FT-Raman spectroscopy
Sylwester Mazurek1, Roman Szostak
1Department of Chemistry, University of Wrocław, 14 F. Joliot-Curie, 50-383 Wrocław, Poland.
Abstract:
The FT-Raman quantification of atorvastatin calcium in tablets was performed using the partial least squares (PLS), principal component regression (PCR) and counter-propagation artificial neural networks (CP-ANN) methods. To compare the predictive abilities of the elaborated models, the relative standard errors of prediction (RSEP) were calculated. The application of PLS, PCR and 6x6 CP-ANN provided models of comparable quality. RSEP error values in the range of 1.9-2.8% for calibration and validation data sets were obtained for the three procedures applied. Four commercial products containing 10, 20 or 40 mg of atorvastatin calcium per tablet were successfully quantified. Concentrations found from the Raman data analysis correlate strongly with the declared values, with a recovery of 98.5-101.3%, and with the results of reference analysis, with the recovery of 98.9-102.1%, for the different models. The proposed procedure can be a fast, precise and convenient method of atorvastatin calcium quantification in commercial tablets.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
UV–Vis Spectrometers
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
UV–Vis Spectroscopy: Woodward–Fieser Rules