Occupational fatalities due to electrocutions in the construction industry

Christopher A Janicak1

  • 1Indiana University of Pennsylvania, Department of Safety Sciences, 136 Johnson Hall, Indiana, PA 15705, USA. cjanicak@iup.edu

Journal of Safety Research
|December 10, 2008
PubMed
Abstract

Related Concept Videos

Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
Survey Safety01:28

Survey Safety

Surveying near highways, rough terrain, or power lines involves significant risks. Working along highways is particularly dangerous and requires the use of warning signs and flagmen. It is safest to avoid working directly on roads and use offsets whenever possible. When highway work is unavoidable, it must follow all safety guidelines. Surveyors should wear bright clothing, such as orange reflective vests, to ensure visibility to motorists, coworkers, and hunters. In construction zones, wearing...
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Equipotential Surfaces and Conductors01:16

Equipotential Surfaces and Conductors

For a conductor in which all charges are at rest, the conductor's surface is equipotential. The electric field is always perpendicular to equipotential surfaces. Therefore, in a conductor with static charges, the electric field just outside the conductor is always perpendicular to the conductor's surface. Any tangential component of the electric field will cause charges to move inside the conductor, which will violate the electrostatic nature of the system. In an electrostatic situation, if a...
Induced Electric Fields01:23

Induced Electric Fields

The fact that emfs are induced in circuits implies that work is being done on the conduction electrons in the wires. What can possibly be the source of this work? We know that it’s neither a battery nor a magnetic field, as a battery does not have to be present in a circuit where current is induced, and magnetic fields never do any work on moving charges. The source of the work is in fact an electric field that is induced in the wires. For example, if a stationary conductor is placed in a...
Electric Field at the Surface of a Conductor01:26

Electric Field at the Surface of a Conductor

Consider a conductor in electrostatic equilibrium. The net electric field inside a conductor vanishes, and extra charges on the conductor reside on its outer surface, regardless of where they originate.
In the 19th century, Michael Faraday conducted the famous ice pail experiment to prove that the charges always reside on the surface of a conductor. The experimental set-up consists of a conducting uncharged container mounted on an insulating stand. The outer surface of the container is...