Enhancement and safety of iomeprol-400 and iodixanol-320 in patients undergoing abdominal multidetector CT
L Romano1, L Grazioli, L Bonomo
1Diagnostic Imaging Department, Cardarelli Hospital, Naples, Italy. luigia.romano@fastwebnet.it
Abstract:
The purpose of this study was to compare iomeprol-400 and iodixanol-320 for contrast enhancement and safety in patients undergoing liver multidetector CT (MDCT). 183 patients undergoing MDCT received equi-iodine (40 gI) iomeprol-400 (n = 91) or iodixanol-320 (n = 92) IV at 4 ml s(-1). Two off-site, independent, blinded readers determined the contrast density (in Hounsfield units (HUs)) in the abdominal aorta, inferior vena cava, portal vein and liver parenchyma during the arterial and portal phases. The mean contrast densities achieved were compared and 95% confidence intervals (CIs) estimated. Heart rate was measured at baseline and at post-dose peak, and a full safety assessment was performed. Study group demographics were comparable. Iomeprol-400 produced significantly greater enhancement of the aorta during the arterial phase (Reader 1: 337.3 HU vs 294.9 HU, 95% CI of difference (19.4, 65.5), p = 0.0004; Reader 2: 325.7 HU vs 295.3 HU, 95% CI of difference (6.6, 54.3), p = 0.01) and greater enhancement of the liver parenchyma during the portal venous phase (Reader 1: 115.1 H vs 108.6 HU, 95% CI of difference (0.27, 12.7), p = 0.04; Reader 2: 115.2 H vs 109.3 HU, 95% CI of difference (-0.1, 11.8), p = 0.05). Similar enhancement of the inferior vena cava and portal vein was noted. Comparably negligible increases in the mean heart rate were observed. Adverse events occurred in 1/91 (1.1%) subjects after iomeprol-400 and 4/92 (4.3%) subjects after iodixanol-320. In conclusion, iomeprol-400 produces greater arterial and portal phase enhancement and has a similarly negligible impact on heart rate and safety.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...