HPLC Measurement of the DNA Oxidation Biomarker, 8-oxo-7,8-dihydro-2’-deoxyguanosine, in Cultured Cells and Animal Tissues
Published on: August 1, 2015
Simultaneous determination of 8-oxo-2'-deoxyguanosine and 8-oxo-2'-deoxyadenosine in DNA using online
Rajinder Singh1, Friederike Teichert, Richard D Verschoyle
1Biocentre, Department of Cancer Studies and Molecular Medicine, University of Leicester, Leicester, UK. rs25@le.ac.uk
Abstract:
Sensitive and reliable methods are required for the assessment of oxidative DNA damage, which can result from reactive oxygen species that are generated endogenously from cellular metabolism and inflammatory responses, or by exposure to exogenous agents. The development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) selected reaction monitoring (SRM) method is described, that utilises online column-switching valve technology for the simultaneous determination of two DNA adduct biomarkers of oxidative stress, 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and 8-oxo-7,8-dihydro-2'-deoxyadenosine (8-oxodA). To allow for the accurate quantitation of both adducts the corresponding [(15)N(5)]-labelled stable isotope internal standards were synthesised and added prior to enzymatic hydrolysis of the DNA samples to 2'-deoxynucleosides. The method required between 10 and 40 microg of hydrolysed DNA on-column for the analysis and the limit of detection for both 8-oxodG and 8-oxodA was 5 fmol. The analysis of calf thymus DNA treated in vitro with methylene blue (ranging from 5 to 200 microM) plus light showed a dose-dependent increase in the levels of both 8-oxodG and 8-oxodA. The level of 8-oxodG was on average 29.4-fold higher than that of 8-oxodA and an excellent linear correlation (r = 0.999) was observed between the two adducts. The influence of different DNA extraction procedures for 8-oxodG and 8-oxodA levels was assessed in DNA extracted from rat livers following dosing with carbon tetrachloride. The levels of 8-oxodG and 8-oxodA were on average 2.9 (p = 0.018) and 1.4 (p = 0.018) times higher, respectively, in DNA samples extracted using an anion-exchange column procedure than in samples extracted using a chaotropic procedure, implying artefactual generation of the two adducts. In conclusion, the online column-switching LC/MS/MS SRM method provides the advantages of increased sample throughput with reduced matrix effects and concomitant ionisation suppression, making the method ideally suited when used in conjunction with chaotropic DNA extraction for the determination of oxidative DNA damage.
More Related Videos
12:15Quantification of three DNA Lesions by Mass Spectrometry and Assessment of Their Levels in Tissues of Mice Exposed to Ambient Fine Particulate Matter
Published on: May 29, 2019
10:33Efficient Purification and LC-MS/MS-based Assay Development for Ten-Eleven Translocation-2 5-Methylcytosine Dioxygenase
Published on: October 15, 2018
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Maxam-Gilbert Sequencing
Challenges of the Maxam-Gilbert Method
The...
Sanger Sequencing
Tandem Mass Spectrometry