Related Experiment Video
Updated: Jun 27, 2026

3D Depth Profile Reconstruction of Segregated Impurities Using Secondary Ion Mass Spectrometry
Published on: April 29, 2020
Trace level impurity method development with high-field asymmetric waveform ion mobility spectrometry: systematic
Elodie Champarnaud1, Alice M-F Laures, Phil J Borman
1Analytical Sciences, GlaxoSmithKline, Gunnels Wood Road, Stevenage, UK.
Abstract:
For the determination of trace level impurities, analytical chemists are confronted with complex mixtures and difficult separations. New technologies such as high-field asymmetric waveform ion mobility spectrometry (FAIMS) have been developed to make their work easier; however, efficient method development and troubleshooting can be quite challenging if little prior knowledge of the factors or their settings is available. We present the results of an investigation performed in order to obtain a better understanding of the FAIMS technology. The influence of eight factors (polarity of dispersion voltage, outer bias voltage, total gas flow rate, composition of the carrier gas (e.g. %He), outer electrode temperature, ratio between the temperatures of the inner and outer electrodes, flow rate and composition of the make-up mobile phase) was assessed. Five types of responses were monitored: value of the compensation voltage (CV), intensity, width and asymmetry of the compensation voltage peak, and resolution between two peaks. Three types of studies were performed using different test mixtures and various ionisation modes to assess whether the same conclusions could be drawn across these conditions for a number of different types of compounds. To extract the maximum information from as few experiments as possible, a Design of Experiment (DoE) approach was used. The results presented in this work provide detailed information on the factors affecting FAIMS separations and therefore should enable the user to troubleshoot more effectively and to develop efficient methods.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Mass Spectrum: Interpretation
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...

