Related Experiment Video
Updated: Jun 27, 2026

Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Treatment of iatrogenic and traumatic tracheal disruptions
G Leoncinii1, L Iurilli, L Boni
1Unit of Thoracic Surgery, San Martino University Hospital, Genoa, Italy. giacomo.leoncini@hsanmartino.it
Background And Aim:
The optimal management of tracheal disruptions is still controversial. It is usually postulated that lesions wider than 1 or 2 centimetres and/or lesions of full-thickness should be treated by surgery at an early stage. Such a statement is not supported by any proven evidence. On the contrary, the conservative management of such injuries has also produced very good results according to recent reports. The aim of this study is to investigate whether conservative treatment can be safely used for wide tracheal lacerations and to assess any possible association between clinical features and modality of treatment.
Methods:
Records of all patients with iatrogenic and traumatic tracheal disruptions observed between January 1992 and December 2006 were collected and retrospectively reviewed. Data regarding mechanism of injury, clinical and morphological features and modalities of treatment were registered. All possible associations between clinical features and modalities of treatment were investigated.
Results:
23 patients were observed overall. There were 6 males and 17 females with a median age of 58 years (range 20-84 yrs). 15 patients had undergone single tube intubation. One patient had his trachea injured during an esophagectomy. Ruptures were secondary to blunt (n = 5) and open (n = 2) trauma in 7 patients. Lesions varied in length between 1 and 7 centimetres (median length 3 centimetres) and all were full-thickness. The time interval until diagnosis varied between 0 and 72 hours (median 6 hours). Respiratory failure was evident in 7 patients. 16 patients (69.5%) with lacerations ranging in length between 1 and 5.5 centimetres (median length 2.75 cm) underwent conservative treatment. Seven patients (30.5%) underwent surgery. The follow up was completed for 16 patients and varied between 15 and 105 months (median 22.5). One patient died after surgical treatment. No mortality or late major sequelae were registered after conservative treatment. Female sex, absence of respiratory failure and delayed diagnosis was associated with the conservative treatment.
Conclusions:
Conservative treatment can play a major role even in cases of wide tracheal lacerations. Clinical rather than morphological features should be regarded as main criteria for treatment. The conservative treatment is particularly indicated in the case of stable respiratory parameters independent of the size and the depth of the lesion.
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...

