Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
[Coronary artery anastomosis using a cloth graft-holder attached to a stabilizer]
1Department of Cardiovascular Surgery, Kainan Hospital, Yatomi, Japan.
Abstract:
Numerous assist devices are usually used for coronary bypass grafting but they make the surgical field cluttered. This study proposes the use of a simple anastomotic method using a cloth graft-holder, which can be attached to a stabilizer. A graft is held between a double-folded cloth of a graft-holder and the graft-holder is attached to the stabilizer using double-stick tape, which provides steady positioning of the graft even in an up-right position. The graft can be positioned parallel with a coronary artery on either side of the stabilizer. The presented method provides a simplified and orderly surgical field without complicated devices and should help achieve a uniform and steady coronary anastomosis.