Related Experiment Video
Updated: Jun 27, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Elaborate treatment of retention in chemoselective chromatography--the retention increment approach and non-linear
1Institute of Organic Chemistry, University of Tübingen, 72076 Tübingen, Germany. volker.schurig@uni-tuebingen.de
Abstract:
The retention increment approach is described which quantifies the association equilibria of a selectand and a selector in complexation and inclusion chromatography. A thermodynamic treatment of enantioselectivity based on retention phenomena in chromatography including entropy/enthalpy compensation and the isoenantioselective temperature is advanced. Kinetic parameters of enantiomerization are discussed. Non-linear effects, both existent and elusive, are described and proposed, respectively. The enantioselectivity pertaining to catalysis vs. chromatography is compared and a unified nomenclature is proposed. Through an educational effort, this account is aimed at providing a deeper insight into chemoselective aspects of chromatography thereby stimulating further research of both established and speculative phenomena of the most intriguing manifestation of chemoselectivity, that is, of enantioselectivity.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Chromatographic Methods: Terminology
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Ion-Exchange Chromatography