Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Silica modified with zirconium oxide for on-line determination of inorganic arsenic using a hydride generation-atomic
Greice T Macarovscha1, Gisele G Bortoleto, Solange Cadore
1Instituto de Química, Universidade Estadual de Campinas, CP 6154, 13083-970, Campinas, SP, Brazil.
Abstract:
In the present work, an on-line pre-concentration system, using SiO(2)/ZrO(2) as solid phase adsorbent, for the determination of low concentrations of arsenic was developed. In this procedure, total inorganic arsenic present in the sample is reduced to As (III) with l-cysteine and the solution is passed into a glass column (varphi(i)=3mm; h=35mm) containing 70mg of SiO(2)/ZrO(2) (100-230 mesh) to retain the As (III), with the solution flowing at 3.2mLmin(-1). After 2min, the concentrated species are eluted with 3molL(-1) HCl (3.2mLmin(-1)) loading a 150muL loop while a 1.0% (m/v) sodium borohydride solution loads the other loop of a FI-HG AAS system. The elution step is carried out during 7s and, at the same time, the SiO(2)/ZrO(2) phase is regenerated for the next concentration cycle. The arsine generated is carried with N(2) (flow rate=90mLmin(-1)) to a quartz cell where the electrothermal atomization process occurs. Under these conditions, a 20-fold enrichment factor is obtained considering the increase of sensitivity in the analytical curve after the concentration step. The limits of detection and quantification were 0.05 and 0.35mugL(-1), respectively, with an injection frequency of about 28h(-1) and relative standard deviation lower than 8%. Four metallurgical reference materials were analyzed with the proposed method after their acid dissolution. The results obtained were in good agreement with certified values.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...