Simultaneous kinetic determination of thiocyanate and sulfide using eigenvalue ranking and correlation ranking in
Ali A Ensafi1, T Khayamian, R Tabaraki
1College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111, Iran. Ensafi@cc.iut.ac.ir
Abstract:
In this work, two toxic compound, sulfide and thiocyanate were determined simultaneously using kinetic spectrophotometry. These anions have shown the catalytic effects on the reaction between iodine and azide. Since the system was nonlinear, a nonlinear model, principal component-wavelet neural network (PC-WNN) was used as the multivariate calibration method. The principal component analysis was used to decrease the dimension of the original matrix. In other words, the scores of the PCs, 5, instead of the original variables, 301, were used as the input for the model. Two methods were used to select the most relevant principal components: eigenvalue ranking and correlation ranking. In this work, eigenvalue and correlation ranking methods have shown better results for thiocyanate and sulfide, respectively, and it can be concluded that these methods are complementary. The WNN has several advantages relative to other types of neural network such as better convergence ability. The data set was divided to calibration, prediction and validation sets. Each set was selected so that the concentrations of the analytes were approximately covered the entire ranges of the analytes. Mean relative error for thiocyanate and sulfide in validation set were 8.5 and 10.6, respectively. Thiocyanate and sulfide can be determined in the range of 60-700ng ml(-1) and 20-400ng ml(-1), respectively. The proposed method was applied for the determination of sulfide and thiocyanate in real samples such as tap, waste and river waters with satisfactory results.
Related Concept Videos
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
2D NMR: Overview of Heteronuclear Correlation Techniques
Kendall's Tau Test
A τ value of +1 indicates that...