Related Experiment Video
Updated: Jun 27, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Determination of chromium(III) and total chromium using dual channels on glass chip with chemiluminescence detection
Waraporn Som-Aum1, Jirasak Threeprom, Haifang Li
1The Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology, Department of Chemistry, Tsinghua University, Beijing 100084, China.
Abstract:
A simple, rapid and sensitive method for the determination of chromium(III) and total chromium using the simple dual T channels on glass chip with negative pressure pumping system and chemiluminescence (CL) detection is presented. The CL reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by chromium(III). Total chromium in form of chromium(III) was achieved after chromium(VI) was completely reduced by acidic sodium hydrogen sulfite. Total chromium could then be determined with the same strategy as the chromium(III). The CL reagent was composed of 1.0x10(-4)mol/L luminol, 1.0x10(-2)mol/L hydrogen peroxide and 0.10mol/L sodium bromide in 0.050mol/L carbonate buffer (pH 11.00). The 1.0x10(-2)mol/L ethylenediaminetetraacetic acid was added into the sample solution in order to improve the selectivity. Chromium(III) could be detected at a notably concentration of 1.6x10(-16)mol/L and a linear calibration curve was obtained from 1.0x10(-15) to 1.0x10(-13)mol/L. The sample and CL reagent consumption were only 15 and 20microL, respectively. The analysis time was less than 1 min per sample with the precision (%R.S.D.) was 4.7%. The proposed method has been applied successfully to the analysis of river water, mineral waters, drinking waters and tap water. Its performance was verified by the analysis of certified total chromium-reference materials and by recovery measurement on spiked synthetic seawater sample.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Determination of Crystal Structures
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors