Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure
H D Kiers1, J M Hofstra, J F M Wetzels
1Department of Nephrology, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands.
Abstract:
Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP) and diastolic blood pressure (DBP) as displayed by the device. In this study we have analysed measured and calculated MAP, obtained by two different oscillometric BP measurement devices in two different patient cohorts. The first cohort included 242 healthy subjects (male 40.5%, 50+/-13 years). BP measurements were performed with a Welch Allyn 5300P device. We found a small but significant difference between measured MAP and calculated MAP (MAP(m-c:) -1.8 mmHg, range -5.7 to 12.9 mmHg, p < 0.001). MAP(m-c) showed a significant, but weak correlation with DBP and SBP. The second cohort included included 134 patients with glomerular diseases (male 63%, 50+/14 years). BP measurements were performed with a Dinamap 487210 device. In this group we also observed a small difference between measured MAP and calculated MAP (+1.7 mmHg, range -15.3 to 28.2 mmHg, p<0.001). MAP (m-c) correlated with age, all blood pressure indices and heart rate. An overall analysis showed that age, SBP, DBP, and type of device are all independently related to MAP (m-c). There is a significant difference between measured and calculated MAP. The difference is small on average; however, this MAP(m-c) can be large in the individual patient. Moreover, there are differences of reported MAP between devices. Our data suggest that calculated and measured MAP cannot be used interchangeably.
Related Concept Videos
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Blood Pressure