Related Experiment Video
Updated: Jun 27, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Multiple daily injections in young patients using the ezy-BICC bolus insulin calculation card, compared to mixed
1University of Newcastle, Department of Endocrinology and Diabetes, John Hunter Children's Hospital, Newcastle, NSW, Australia. donald.anderson@hnehealth.nsw.gov.au
Objective:
To describe the easy bolus insulin calculation card (ezy-BICC) approach to multiple daily injections and to compare in an observational study, the haemoglobin A1c (HbA1c) achieved while using ezy-BICC, mixed insulin injections and continuous subcutaneous insulin infusion (CSII).
Methods:
HbA1c results from 7121 clinic visits by 573 patients aged 1-20 yr using the three methods between June 2000 and July 2008 were reviewed.
Results:
For mixed insulin median, mean and SD HbA1c were 8.3%, 8.3%, 1.33, for ezy-BICC, 7.6%, 7.7%, 1.40, and for CSII, 7.6%, 7.8%, 1.31. HbA1c increases with age significantly more in those using CSII (p < 0.001). By regression, compared with mixed insulin HbA1c is 0.7% lower using ezy-BICC (p < 0.018) and 1.5% lower using CSII (p < 0.001). For patients using CSII compared with <6 yr, those 6-12 yr have HbA1c 0.7% higher (p < 0.001), 12-15 yr 1.0% higher (p < 0.001) and 15-20 yr 1.2% higher (p < 0.001). For subjects >12 yr, HbA1c is lower while using ezy-BICC than CSII. HbA1c increases 0.2% per yr following diagnosis for 2.8 yr. In those who change from mixed insulin to ezy-BICC after this time, the mean HbA1c is 0.5% lower by 9 months, 0.7% lower at 21 months and 0.6% lower at 24 months (p < 0.05).
Conclusions:
The ezy-BICC system is inexpensive and convenient and allows patients to vary meal size. Subjects achieve lower HbA1c while using CSII and ezy-BICC MDI than with mixed insulin. Very young subjects achieve excellent HbA1c using CSII, but for 12 to 20 yr-old patients, ezy-BICC results in lower HbA1c than CSII for a lower cost.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into rapid-acting...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
IV Infusion to Oral Dosing: Conversion Methods