[Non-invasive measurement of cardiac output by the CO2 rebreathing method and its reliability in clinical practice]
Related Experiment Video
Updated: Aug 14, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
N Kuji1, O Tochikubo, M Shimizu
1Second Department of Internal Medicine, Yokohama City University School of Medicine.
Abstract:
A Commercially available, non-invasive system for estimation of cardiac output by the CO2-rebreathing method (Sensormedicus MMC4400) was evaluated to determine its reliability in clinical practice. Values of cardiac output were obtained at rest and during mild to moderate bicycle ergometer work in patients with ischemic heart disease or hypertension. Cardiac output measured by the CO2-rebreathing method was significantly correlated with that measured simultaneously by dye dilution or thermodilution methods. Cardiac output values determined by the CO2-rebreathing method were the same as those obtained by the two invasive methods in reproducibility. When cardiac output and Vo2 were normalized for body weight, they were significantly correlated with each other. This result was obtained both by the CO2-rebreathing method, and by the two invasive methods. These results indicate that MMC4400 will provide a value for cardiac output substantially the same as that obtained by using more laborious invasive methods. Clinical use of the CO2-rebreathing method has been limited by technical difficulties. However, the recently developed non-invasive cardiac output measurement system (MMC4400) uses a microcomputer to analyze the results, and the operator can determine the values for cardiac output easily. Furthermore, it simultaneously measures VO2, VCO2 and VE, so the operator can estimate the measured values for cardiac output with background information on ventilatory gas analysis. Determination of cardiac output through the use of the CO2-rebreathing method is suitable particularly for exercise studies, and it is expected to be a useful device, in the near future, for evaluating cardiac function of patients with primary cardiac diseases.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Measurement of Blood Pressure

