Prediction of retention times and peak widths in temperature-programmed gas chromatography using the finite element
Fredrik Aldaeus1, Yasar Thewalim, Anders Colmsjö
1Stockholm University, Department of Analytical Chemistry, SE-106 91 Stockholm, Sweden.
Abstract:
Optimization of separations in gas chromatography is often a time-consuming task. However, computer simulations of chromatographic experiments may greatly reduce the time required. In this study, the finite element method was used to predict the retention times and peak widths of three analytes eluting from each of four columns during chromatographic separations with two temperature programs. The data acquired were displayed in predicted chromatograms that were then compared to experimentally acquired chromatograms. The differences between the predicted and measured retention times were typically less than 0.1%, although the experimental peak widths were typically 10% larger than expected from the idealized calculations. Input data for the retention and peak dispersion calculations were obtained from isothermal experiments, and converted to thermodynamic parameters.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatographic Methods: Terminology
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...