Related Experiment Video
Updated: Jun 27, 2026

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
Quantitative evaluation of the systemic effects of transposed basilic vein to brachial artery arteriovenous fistula:
N Saratzis1, A Saratzis, P A Sarafidis
11st Department of Surgery and Vascular Surgery, Aristotle University of Thessaloniki, Papageorgiou General Hospital, Thessaloniki, Greece.
Background:
The transposed basilic vein to brachial artery arteriovenous fistula (BBAVF) constitutes an alternative autogenous vascular access (VA) site for chronic hemodialysis (HD); however, the hemodynamic effects of this procedure have not been adequately studied. The purpose of this study is to evaluate the effects of BBAVF on systemic arterial pressure, cardiac function, and upper limb ischemia (ischemic steal syndrome) utilizing reproducible quantitative methods.
Methods:
Ten consecutive patients (eight males; mean age: 65.10+/-2.87 yrs) scheduled to undergo a brachial-basilic vein transposition were included, excluding patients with cardiac failure. Blood flow volume at the level of the AVF, systemic arterial pressure (SAP), cardiac output (CO) and digital brachial index (DBI) were measured intra-operatively, before and after the creation of the BBAVF, and post-operatively on the 30th post-operative day and on the 3rd post-operative month.
Results:
SAP and DBI at 30 days and 3 months post-operatively were significantly lower compared to baseline. CO at 30 days and 3 months post-operatively was significantly higher compared to baseline; however, none of the patients developed cardiac failure. DBI remained >or=0.6 at 3 months, except in one case (0.59). Blood flow volume at the level of the AVF was positively correlated with CO levels on the 30th post-operative day. Mean clinical follow-up was 12 months (range: 4-15 months). In two cases (20%) the AVF was thrombosed (4th and 10th post-operative month).
Conclusion:
This prospective quantitative study proves that the BBAVF does impact significantly upon SAP, CO, and DBI; however, it is safe in terms of high-output cardiac failure and ischemic steal syndrome. The authors state that they do not have any commercial, proprietary, or financial interest in any products or companies described in this article.