Related Experiment Video
Updated: Jun 27, 2026

Three-Dimensional Reconstruction of Orbital Fractures
Published on: May 16, 2025
Computed tomography imaging strategies and perspectives in orbital fractures
Denise Takehana Dos Santos1, Jefferson Xavier Oliveira, Michael Walter Vannier
1Department of Radiology, College of Dentistry, University of São Paulo, São Paulo, Brazil.
Objective:
The objective of this study was to demonstrate the sensitivity and specificity of multislice computed tomography (CT) for diagnosis of orbital fractures following different protocols, using an independent workstation.
Materials And Methods:
CT images of 36 patients with maxillofacial fractures (symptomatic to orbit region) who were submitted to multislice CT scanning were analyzed, retrospectively. The images were interpreted based on 5 protocols, using an independent workstation: 1) axial (original images); 2) multiplanar reconstruction (MPR); 3) 3D images; 4) association of axial/MPR/3D images and 5) coronal images. The evaluated anatomical sites were divided according to the orbital walls: lateral (with or without zygomatic frontal process fracture); medial; superior (roof) and inferior (anterior, medial). The collected data were analyzed statistically using a validity test (Youden's J index; p<0.05). The clinical and/or surgical findings (medical records) were considered as the gold standard to corroborate the diagnosis of the anatomical localization of the orbital fracture.
Results:
3D-CT scanning presented sensitivity of 78.9%, which was not superior to that of MPR (84.0%), axial/MPR/3D (90.5%) and coronal images (86.1%). On the other hand, the diagnostic value of axial images was considered limited for orbital fractures region, with sensitivity of 44.2%.
Conclusions:
Except for the axial images, which presented a low sensitivity, all methods evaluated in this study showed high specificity and sensitivity for the diagnosis of orbital fractures according to the proposed methodology. This protocol can add valuable information to the diagnosis of fractures using the association of axial/MPR/3D with multislice CT.
More Related Videos
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
09:11Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography (Micro-CT) Imaging Method
Published on: October 27, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...