Internal adaptation of cast titanium crowns
Sicknan Soares da Rocha1, Gelson Luis Adabo, Ricardo Faria Ribeiro
1Health Science Institute, University Paulista (UNIP), Goiânia, GO, Brazil.
Journal of Applied Oral Science : Revista FOB
|December 18, 2008
Summary
This study found that neither changing the liquid concentration nor the mold temperature significantly affected the internal fit of titanium crowns. Optimal fit was observed with 100% liquid concentration at both 430°C and 600°C mold temperatures.
Area of Science:
- Biomaterials Science
- Dental Materials Science
- Casting Technology
Background:
- Titanium crowns are widely used in restorative dentistry due to their biocompatibility and mechanical properties.
- Ensuring a precise fit of dental prosthetics is crucial for long-term success and preventing complications.
- The Rematitan Plus investment material is specifically designed for titanium casting, but its efficacy in achieving optimal crown adaptation requires further investigation.
Purpose of the Study:
- To evaluate the influence of investment liquid concentration and mold temperature on the internal misfit of commercially pure titanium crowns.
- To determine the optimal parameters for casting titanium crowns using the Rematitan Plus investment material to minimize internal discrepancies.
Main Methods:
- Commercially pure titanium crowns were cast using the Rematitan Plus investment material.
- Two concentrations of the specific investment liquid (100% and 75%) were tested.
- Three mold temperatures (430°C, 515°C, and 600°C) were employed during the casting process.
- Internal misfit was quantified by measuring the cement layer area between the crown and die using image analysis software.
Main Results:
- Neither the dilution of the investment liquid nor the increase in mold temperature significantly affected the internal fit of the cast titanium crowns.
- The lowest mean internal misfit values were observed in groups using 100% liquid concentration at 430°C (7.25 mm² ± 1.59) and 600°C (8.8 mm² ± 2.25).
- These two conditions (430°C/100% and 600°C/100%) showed statistically similar levels of internal misfit.
Conclusions:
- The tested variations in investment liquid concentration and mold temperature do not significantly impact the internal fit of titanium crowns cast with Rematitan Plus.
- Further research may be needed to explore other factors influencing the adaptation of titanium castings.
- Clinicians can consider using 100% liquid concentration with mold temperatures of 430°C or 600°C, as they yield comparable and acceptable internal misfit levels.