Related Experiment Video
Updated: Jun 27, 2026

Accurate and Phenol Free DNA Sexing of Day 30 Porcine Embryos by PCR
Published on: February 14, 2016
"GenderPlex" a PCR multiplex for reliable gender determination of degraded human DNA samples and complex gender
Anna Esteve Codina1, Harald Niederstätter, Walther Parson
1Institute of Legal Medicine, Innsbruck Medical University, Müllerstrasse 44, 6020 Innsbruck, Austria.
Abstract:
The amelogenin test integrated in most commercial polymerase chain reaction (PCR) multiplex kits is routinely used in the forensic field for gender determination of DNA samples. It has been demonstrated that this test is not entirely reliable. Males with deletions in the homologous amelogenin part on the Y chromosome (AMELY) were erroneously typed as females due to lack of Y-specific amelogenin amplification. Also, primer binding site mutations that result in a failure to amplify the AMELY or the X-chromosomal part (AMELX) have been observed. For clarification of such phenomena, a new PCR multiplex (GenderPlex) is presented, co-amplifying two different regions of the amelogenin gene (55/58 and 106/112 bp for the AMELX and AMELY alleles, respectively), a 93-bp sequence stretch of the SRY gene and four mini-X-STR loci DXS7424, DXS8378, DXS6803 and GATA172D05 (maximum product size less than 140 bp). This strategy helps with the evaluation of samples for the presence of amelogenin-based primer site mutations and confirms a male genotype by the absence of heterozygote X-STR alleles and the presence of an SRY-related peak. The short amplicon sizes of all involved loci proved to be beneficial in a study on artificially degraded DNA. Furthermore, we demonstrate by means of sensitivity, human specificity and mixture studies that the multiplex is suitable for investigations in the forensic scene. Finally, the performance of the GenderPlex was evaluated on a west Eurasian population sample from Austria comprising 166 male and 104 female individuals.
More Related Videos
11:49Enhanced Genetic Analysis of Single Human Bioparticles Recovered by Simplified Micromanipulation from Forensic ‘Touch DNA’ Evidence
Published on: March 9, 2015
08:22A Robust Polymerase Chain Reaction-based Assay for Quantifying Cytosine-guanine-guanine Trinucleotide Repeats in Fragile X Mental Retardation-1 Gene
Published on: September 16, 2019
Related Concept Videos
The Ratio of X Chromosome to Autosomes
Normal male Drosophila has a ratio of one X chromosome to two sets of autosomes. In contrast, normal female Drosophila...
DNA Isolation