Related Experiment Video
Updated: Jun 27, 2026

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
Posterior lamellar disc dislocation into the vitreous cavity during descemet stripping automated endothelial
Martin Grueterich1, Elisabeth Messmer, A Kampik
1Department of Ophthalmology, University Eye Hospital, Ludwig-Maximilians University, Munich, Germany. martin.grueterich@med.uni-muenchen.de
Abstract:
We present a case of a dislocated posterior lamellar lenticule into the vitreous cavity during Descemet stripping automated endothelial keratoplasty. After insertion of the donor disc in a partially vitrectomized eye with partial iris loss, the graft dislocated into the vitreous cavity. With a standard 3-port vitrectomy and the help of perflourocarbon fluid, the graft was lifted into the anterior segment of the eye and firmly attached to the recipient cornea using liquid-air exchange. The postoperative follow-up was without complications. The cornea was clear at the third day after surgery without recurrent graft dislocation.