Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
Coherent anti-Stokes Raman scattering microscopy of samples probed with Gaussian volumes
1ENEA, via Anguillarese 301, S. Maria di Galeria, Rome, Italy. michele.marrocco@casaccia.enea.it
Abstract:
Coherent anti-Stokes Raman scattering (CARS) microscopy is becoming increasingly popular to characterize biochemical samples. Within this context, we show that theoretical analysis can still be accomplished under the simple assumption of Gaussian volumes instead of spatial shapes obtainable from diffraction necessary to describe the tight-focusing condition realized within the focus of microscopes with high numerical apertures. The assumption, common in other physical and chemical spectroscopic techniques based on microscopy (e.g., fluorescence correlation spectroscopy, photon counting histogram) and never applied to CARS, is here used to determine the expression of the anti-Stokes electric field. Contrary to the standard approach resorting to numerical methods, we find that either the field is analytical for certain shapes of the Raman scatterer or the numerical reconstruction is strongly limited. In addition, we examine tests against two typical problems found in the literature, namely, a description of CARS radiation patterns and CARS imaging. With regard to the latter, we remark that the loss of spatial symmetry, the treatment of which is onerous in standard CARS microscopy because of possible separations between the microscope focus and the Raman scatterer, can be handled with ease in the limit of Gaussian volumes. An example is considered for polystyrene beads that are usually employed as test model of a CARS response of relevant biochemical samples.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Total Internal Reflection Fluorescence Microscopy
Two-Dimensional Microscopy in Microbiology
Confocal Fluorescence Microscopy