Related Experiment Video
Updated: Jun 27, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Right ventricular free wall circumferential strain reflects graded elevation in acute right ventricular afterload
Eun Joo Cho1, Panupong Jiamsripong, Anna M Calleja
1Translational Ultrasound Research Laboratory, Division of Cardiovascular Diseases, Mayo Clinic, Scottsdale, Arizona, USA.
Abstract:
This study was designed to evaluate the concurrent changes in the right ventricular free wall (RVFW) movement in experimentally induced, acute mild, moderate, and severe right ventricle (RV) afterload conditions. In 14 open-chest pigs (weight 43 +/- 4 kg) with preserved pericardia, acute mild (>35 and <50 mmHg), moderate (> or =50 and < or =60 mmHg), and severe (>60 mmHg) increases in RV systolic pressure (RVSP) were induced by constriction of the pulmonary artery. At each step, longitudinal, radial, and circumferential strains and strain rates were measured in both the RVFW and the interventricular septum. The mean RVSPs were 31.0 +/- 4.3 mmHg at baseline and 41.1 +/- 2.7 mmHg during mild, 52.7 +/- 3.4 mmHg during moderate, and 61.7 +/- 1.6 mmHg during severe afterload conditions. The RVFW circumferential strains showed significant differences among baseline, mild, moderate, and severe afterload conditions (-10.5 +/- 3.9, -8.3 +/- 3.3, -5.4 +/- 2.7, and -7.5 +/- 5.3%, respectively, P = 0.008) and had significant linear correlation with RVSP (r = 0.636, P < 0.001) if the severe condition was excluded. Decrease of the RVFW circumferential strain magnitude is the most distinct response in acute mild and moderate RV afterload that could aid in detection of clinical conditions associated with acutely increasing RV afterload.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Related Concept Videos
Mitral Regurgitation I: Introduction
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Mitral Stenosis I: Introduction
Heart Failure II: Pathophysiology
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...