Related Experiment Video
Updated: Jun 27, 2026

Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Hemiepiphyseal stapling for angular deformity correction around the knee joint in children with multiple epiphyseal
Tae-Joon Cho1, In Ho Choi, Chin Youb Chung
1Seoul National University Children's Hospital, Seoul, Korea.
Background:
Angular deformity around the knee joint in patients with multiple epiphyseal dysplasia (MED) causes alteration in knee biomechanics as well as cosmetic problem. We report angular correction by hemiepiphyseal stapling (HES) and physeal behavior after stapling removal in MED patients.
Methods:
In 17 knees of 9 MED patients, 16 distal femoral and 8 proximal tibial physes were stapled. Age at operation ranged from 8.2 to 13.9 years. Thirteen knees were in valgus alignment and 3 in varus and were followed up for an average of 3.9 years. Angular deformity change was evaluated by the anatomical lateral distal femoral angle or anatomical medial proximal tibial angle. Mechanical axis deviation was defined as the percentage ratio of distance from the knee joint center to mechanical axis divided by half the width of the tibial plateau.
Results:
Amount of angular correction by HES at the distal femur was 15.3 +/- 6.4 degrees for an average of 17.4 months, and at the proximal tibia, 8.6 +/- 2.0 degrees for an average of 13.4 months. Twelve distal femoral physes remained stationary (angular change <3 degrees) and 4 rebounded (loss of correction >3 degrees) after staple removal, whereas 5 proximal tibial physes remained stationary, 2 rebounded, and 1 was progressive. Neither hardware problems nor clinical complications other than overcorrection or undercorrection were encountered. At the latest follow-up, mechanical axis deviation remained within +/-50% in 14 of 17 knees. The remaining 3 knees failed because of premature closure of the distal femoral physis, causing undercorrection of the deformity, insufficient rebound of an overcorrected knee, or progressive angular change after staple removal.
Conclusions:
Hemiepiphyseal stapling is effective for angular correction in MED with minimal surgical insult. However, as physeal behavior after staple removal is rather unpredictable, overcorrection over zone 1 should be avoided, and close monitoring is mandatory until skeletal maturity.
Related Concept Videos
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary or...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...