Related Experiment Video
Updated: Jun 27, 2026

A Method for Tracking the Time Evolution of Steady-State Evoked Potentials
Published on: May 25, 2019
The ERP signature of sound rise time changes
Jennifer M Thomson1, Usha Goswami, Torsten Baldeweg
1Harvard Graduate School of Education, Larsen 322, 14 Appian Way, Cambridge, MA 02138, USA. thomsoje@gse.harvard.edu
Abstract:
Sounds, whether speech or non-speech, vary in how rapidly their peak amplitudes are reached. The time taken for sounds to reach their maximum amplitude is known as the rise time and this variable is an important perceptual cue for representation of the sound amplitude envelope. In the experiments described here healthy adult volunteers passively listened to tones varying in rise time. An oddball design was used and both N1 and MMN components were examined. Experiment 1 contrasted tone stimuli of 15 ms vs. 185 ms rise time. The shorter 15 ms rise time stimuli elicited an N1b over central frontal electrodes of significantly greater amplitude than the 185 ms rise time stimuli. MMN was also observable for both the 15 ms and 185 ms rise time tones when the same stimuli served as deviant vs. standard. Experiment 2 explored the possible confound of rise time and overall stimulus intensity change (tones with shorter rise times sound louder). New stimuli were created in which overall stimulus intensity between short and long rise times was perceptually matched. N1b amplitude differences to the contrastive rise times were still observed, suggesting that N1b may reflect an auditory cortex detector mechanism sensitive to changes in rise time, relatively independently of sound intensity changes. These findings are discussed with reference to their implications for speech perception processes.
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Beats
Basic Discrete Time Signals
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...
Sound Waves: Resonance
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...

