Related Experiment Video
Updated: Jun 27, 2026

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
Effect of phenyl sepharose ligand density on protein monomer/aggregate purification and separation using hydrophobic
Justin T McCue1, Philip Engel, Jörg Thömmes
1Biogen Idec Corporation, Bioprocess Development, 14 Cambridge Center, Cambridge, MA 02142, USA. Justin.mccue@biogenidec.com
Abstract:
In the large-scale manufacturing and purification of protein therapeutics, multiple chromatography adsorbent lots are often required due to limited absorbent batch sizes or during replacement at the end of the useful column lifetime. Variability in the adsorbent performance from lot to lot should be minimal in order to ensure that consistent product purity and product quality attributes are achieved when a different lot or lot mixture is implemented in the process. Vendors of chromatographic adsorbents will often provide release specifications, which may possess a narrow range of acceptable values. Despite relatively narrow release specifications, the performance of the adsorbent in a given purification process could still vary from lot to lot. In this case, an alternative use test (one that properly captures the lot to lot variability) may be required to determine an acceptable range of variability for a specific process. In this work, we describe the separation of therapeutic protein monomer and aggregate species using hydrophobic interaction chromatography, which is potentially sensitive to adsorbent lot variability. An alternative use test is formulated, which can be used to rapidly screen different adsorbent lots prior to implementation in a large-scale manufacturing process. In addition, the underlying mechanism responsible for the adsorbent lot variability, which was based upon differences in protein adsorption characteristics, was also investigated using both experimental and modeling approaches.
More Related Videos
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Affinity Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Detergent Purification of Membrane Proteins
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...