Echocardiographic parameters of mechanical synchrony in healthy individuals
Cristina Conca1, Francesco Fulvio Faletra, Chinami Miyazaki
1Division of Cardiology, Fondazione Cardiocentro Ticino, Lugano, Switzerland.
Abstract:
Definition and validation of the ranges of normal values and agreement among echocardiographic measures of mechanical synchrony in healthy subjects are mostly lacking. The aims of this study were (1) to assess the ranges of normal values for 5 tissue Doppler imaging parameters, real-time 3-dimensional echocardiographic measures, and speckle-tracking measures of mechanical synchrony; (2) to evaluate interinstitutional variability; (3) to compare the ranges of normal values with those reported in previous research; and (4) to analyze the agreement among all parameters in the same healthy subject. Time to peak systolic velocity (Ts), the delay between Ts at the basal septal and lateral segments, peak velocity difference, strain derived by tissue Doppler imaging, Ts derived by tissue synchronization imaging, systolic synchrony index (SSI) derived by real-time 3-dimensional echocardiography, and longitudinal and radial strain derived by speckle tracking were prospectively collected and analyzed at 2 different institutions in 160 consecutive healthy subjects. The ranges of normal values, expressed as means +/- 2 SDs, were 30.32 +/- 29.36 ms for the SD of Ts, 15.51 +/- 99.88 ms for septal-lateral delay, 60.75 +/- 81.62 ms for peak velocity difference, 33.07 +/- 29.96 ms for tissue synchronization imaging, 34.16 +/- 23.26 ms for the SD of strain, 2.74 +/- 2.16% for SSI, 28.91 +/- 23.02 ms for the SD of longitudinal strain, and 10.4 +/- 6.31 ms for radial strain. There was large interinstitutional variability for all parameters. Three-dimensional SSI and radial strain were within the published upper range limit for healthy subjects. Ninety percent of healthy subjects were consistently classified to be synchronous by 1 parameter. With a composite index, more subjects than expected showed dyssynchrony (10% vs 2.5%). In conclusion, 3-dimensional SSI and radial strain were the most reproducible parameters and consistently discriminated normal healthy subjects from the cardiac resynchronization therapy volume responders.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...