Purpose Of Review:
To analyze the strength and weakness of various imaging tools for systolic dyssynchrony assessment in the cardiac resynchronization therapy (CRT) era. Also, controversies and problematic issues of the recent predictors of response to cardiac resynchronization therapy study were addressed.
Recent Findings:
Despite published data from experienced centers that echocardiographic parameters of systolic dyssynchrony assessment with defined cutoff values were able to predict favorable response to CRT (septal-to-posterior wall delay by M-mode of 130 ms, tissue Doppler imaging of septal-to-lateral wall delay of 65 ms and Ts-SD of 33 ms, and speckle tracking delay in septal-to-posterior wall radial strain of 130 ms), the recent predictors of response to cardiac resynchronization therapy (PROSPECT) study did not concur with the observations. However, the latter study was flawed in multiple areas including site selection bias, dyssynchrony training, and selection of echocardiography equipment, echo core-laboratory experience and echocardiographic image quality surveillance. These factors acting in concert contributed to the high variability of dyssynchrony parameters, high echocardiographic data missing rate, and inconsistent measurement, which will not determine if dyssynchrony predicts a higher response rate than QRS duration alone.
Summary:
There is a learning curve for dyssynchrony assessment. Without proper dyssynchrony training and experience accumulation in a large number of implanting centers worldwide, a rush into multicenter trials that only focus on experienced device implantation will not be possible to replicate the role of dyssynchrony assessment.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: